Corrosion Testing Standards

The test standard summaries are for general guidance only. Though believed to be accurate at the time of writing, this may change over time. So this information should not be used as a substitute for referring to a complete test standard, at an appropriate revision level.

Note: the terms salt spray, salt mist and salt fog are all in wide spread use within corrosion test standards. In this context they can be considered to be equivalent and interchangeable terms.

AA-0324 (AA-P 184)

Salt spray corrosion test used to test the effectiveness of corrosion protection systems

Can be used to test the relative resistance to corrosion of metallic materials with or without temporary or permanent corrosion protection, when exposed to a salt spray climate (neutral salt spray or acetic acid salt spray or copper accelerated acetic acid salt spray) at an elevated temperature.

Test specimens are placed in an enclosed chamber and exposed to a continuous indirect spray of neutral (pH 6.5 to 7.2) salt water solution, which falls-out on to the specimens at a rate of 30 to 40 ml/80cm²/24 hours, in a chamber temperature of +35°C or +50°C. This climate is maintained under constant steady state conditions. The test duration is variable. The chamber should not be filled to more than 50% capacity.

In all other respects this test is based upon ISO9227.

For further information on ISO standards visit; www.iso.org

Note: many ISO test standards have been harmonized with other European standards and these are now prefixed ‘EN’ (Euro Norm) or ‘** EN’ – where ** are the letters representing a European country/language code, for example ‘BS EN’ for a harmonized British standard in English language.