1 pen chart recorder paper type
|
ACC08/1
|
1 pen, 100mm/4” wide, paper strip chart recorder, coupled to a temperature sensor, for continuously recording the chamber air temperature (°C).
|
F
|
|
|
2 pen chart recorder paper type
|
ACC08/2
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
2 pen, 100mm/4” wide, paper strip chart recorder, coupled to temperature and humidity sensors, for continuously recording the air temperature (°C) and relative humidity (%RH).
|
F
|
|
|
Hand held pH meter
|
ACC11
|
Digital pH meter, for measuring the pH of salt solution fallout over range 0-14 pH with a resolution of 0.01 pH. Supplied complete with buffers.
|
A
|
|
|
Hand held temperature & humidity probe
 |
ACC28
|
Precision hand-held thermo-hygrometer for independently checking the chamber temperature and humidity. Includes a special salt resistant measuring probe mounted on an extension cable. Range: -40 to +85°C & 0 to 100%RH. Requires any size entry port (see option ACC10) to access the chamber interior.
|
A
|
|
|
Re-transmission of temperature & humidity
|
ACC36
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
Re-transmission of chamber temp & humidity as 2 x 0-10VDC signals via externally mounted socket. For remote data logging.
|
F
|
|
|
Thermometer pocket in air saturator
|
ACC37
|
This option provides a 6mm/0.24” internal diameter thermopocket, mounted in the air saturator. Users may insert their own independent temperature probe into this, if they wish to independently monitor the air saturator temperature.
|
F
|
|
|
2 pen chart recorder - paperless type ††
 |
ACC40/2
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
2 pen paperless chart recorder, coupled to temperature and humidity sensors, for continuously recording the chamber air temperature (°C) and relative humidity (%RH). Records values electronically on to a virtual chart. Data can be stored on integral USB drive and/or downloaded to a network computer running appropriate software (see option ACC41) via RJ45 (Ethernet) connector.
†† Recorder is free-standing for 120 Ltrs chambers, & chamber mounted for other models.
|
F
|
|
|
Software for paperless chart recorder ACC40/2
|
ACC41
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
Software for paperless chart recorder (separate option ACC40/2). When loaded on a network computer enables monitoring and graphical storage of actual chamber temperature and humidity profiles.
For accessory ACC40/2
|
A
|
|
|
Temperature data logger
|
ACC50
|
A battery powered, chamber mounted data logger and temperature sensor. Continuously records the chamber air temperature (°C). Logs can be downloaded to a computer running appropriate software (provided).
|
F
|
|
|
Temperature & humidity data logger
|
ACC52
|
As ACC50, but also records humidity (%RH) levels using a combined temperature and humidity sensor. Requires any size entry port (see option ACC10) to access the chamber interior.
|
F
|
|
|
Salt solution reservoir low level alarm
|
ACC70
|
Operates if the salt solution level falls below requirement for approximately18 hours testing low level alarm at 1-2ml/hour fall-out rates. Sounds audible alarm and displays warning message. If reservoir is not refilled within 18 hours the running chamber program will automatically pause/stop.
|
F
|
|
|
Hand-held salinity refractometer
 |
ACC100
|
A salinity refractometer optimized to give a direct reading of percentage sodium chloride in the range 0 to 28%, with automatic temperature compensation. A single drop of the salt solution to be measured is placed on the viewing window, using the pipette supplied, and its salinity read against a high contrast scale, graduated in % sodium chloride, to give an accurate reading.
|
A
|
|
|
Salt solution consumption sensor
|
ACC102
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
This option comprises of an electronic liquid flow sensor mounted inside the chamber and sensor situated in-line between the salt solution reservoir and the salt spray atomizer. The sensor measures the flow of salt solution from the reservoir to the atomizer. The output from the is displayed digitally at the chamber HMI as instantaneous consumption in ml per min and total consumption in ml.
|
F
|
|
|
Temperature & humidity sensor extension cable
|
ACC104
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
Extension cable to allow chamber sensor to be positioned (& chamber to be controlled) at any point inside chamber.
|
A
|
|
|
Fallout measuring kit
 |
ACC108
|
Comprises of 4 x 100ml measuring cylinders and 4 x 100mm funnels, for manually collecting and measuring salt spray fall-out inside a chamber, during salt spray testing.
|
A
|
|
|
Software for suffix iP chambers
 |
ACC120
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
When loaded on a suitable network connected computer, this software allows logging of chamber variables and editing of chamber programs. It uses a graphics based display, which mimics the chamber control interface.
|
A
|
|
|
Software ACC120 pre-installed on Laptop Computer
 |
ACC122
ONLY AVAILABLE FOR PREMIUM SALT SPRAY CHAMBERS
|
This option comprises of the ACC120 software pre-installed on a laptop computer. A wireless router is also included for the chamber, to enable the computer and chamber to communicate wirelessly, if required. Everything is configured and ready to run.
|
A
|
|
|
Real-time monitoring of chamber control variables (iPad Application)  |
ACC124 |
This option comprises of an iPad application for wireless monitoring of chamber variables such as temperature, humidity and salt fog fall-out rate.
Only available for chambers equipped with Electronic Catchpots - optional accessory ACC116. Both the iPad and the chamber need to be connected to the same Local
Area Network (LAN). iPad not supplied. |
A |